1. Ultrasonic flowmeter

2. What is the reason for the ultrasonic flowmeter displaying 0000 despite having flow rate

The main reason for the ultrasonic flowmeter displaying 0000 despite having flow rate is due to abnormal signal reception or incorrect parameter settings, which result in the system determining no effective flow rate. 1. Installation and sensor issues: Improper installation position: too far away from the pipe wall, close to turbulent areas such as bends/valves, can cause distortion of ultrasonic signals. Sensor failure: dirty transducer surface, dry coupling agent, short circuit of the circuit or corrosion of the joint, requiring cleaning, testing or replacement of coupling agent. Failure: special coupling agent needs to be reapplied to ensure sound wave transmission. 2 Abnormal working conditions and medium flow rate: When the flow rate is below the minimum detection threshold of the flowmeter (usually 0.1m/s), it cannot trigger a change in the measured medium state. High temperature gasification, excessive bubbles or impurities will affect the ultrasonic penetration rate. Temperature/pressure exceeding the limit: beyond the calibration range of the sensor (commonly -30 ℃~160 ℃), a heat dissipation or pressure reduction device needs to be installed System configuration error, parameter settings do not match: parameters such as pipe diameter, medium type (water/oil/gas), range, etc. need to be matched with the physical object. Signal processing exception: Converter water ingress or circuit board failure can cause signal decoding failure Quick troubleshooting steps: ① Check if the installation spacing of the sensor meets the formula requirements (pipe diameter x coefficient) ② Clean the surface of the transducer and reapply the coupling agent ③ Confirm that the pipeline is full and the flow rate is greater than 0.3m/s ④ Check if the parameter settings match the actual medium ⑤ Use an analog signal generator to detect if the converter is working properly. If the above operation is ineffective, a portable ultrasonic flowmeter should be used for on-site calibration and comparison, or contact the manufacturer to test the sensor transmission power.

3. What are the well-known brands of steam flow meters?

Currently, well-known brands of steam flow meters are divided into two camps: domestic and international, covering different application scenarios of high, medium, and low-end. Suitable products can be selected according to working condition accuracy, temperature and pressure resistance requirements, and budget.

.

1. Domestic Brands 1 Chongqing Qingtian Teke: Southwest flow meter leader, high-end substitute benchmark for domestic steam flow meters. The core products include vortex street, orifice plate, V-cone, ultrasonic flowmeter, etc., with an accuracy of ± 0.5% FS, temperature resistance of -40 ℃ to 350 ℃, and a maximum pressure resistance of 40MPa. Equipped with integrated temperature and pressure compensation to enhance anti vibration design, built-in intelligent signal processing chip, widely used in industries such as thermoelectric and chemical. Chongqing Chuanyi CYY: a leading and listed company in domestic automation instruments, participated in the formulation of national standards for steam flow meters. The core products are CVM series vortex flowmeter and differential pressure flowmeter, with a temperature resistance of 550 ℃ and a pressure resistance of 35MPa. 3. Xingao

『SILVER Official Website SERVICE』

Copyright2026SILVER E-Commerce
+86 15365082610